Application Guide

[56]
Software User's
Manual
Version 3.0
Configuration > Security > Switch > RMON > History
RMON History Configuration
Configure RMON History table on this page. The entry index key is ID.
Add New Entry
Setting Description
Delete Check to delete the entry. It will be deleted during the next save.
ID Indicates the index of the entry. The range is from 1 to 65535.
Data Source
Indicates the port ID which wants to be monitored. If in stacking switch, the
value must add 1000000*(switch ID-1). For example, if the port is switch 3 port
5, the value is
3
000005.
Interval
Indicates the interval in seconds for sampling the history statistics data. The
range is from 1 to 3600, default value is 1800 seconds.
Buckets
Indicates the maximum data entries associated with this History control entry
stored in RMON.
The range is from 1 to 3600, default value is 50.
Buckets
Granted
The number of data shall be saved in the RMON.