Add/Edit User
Click the Add New User button to add a new user. Also, you can click User Name to edit a user.
User Name
Setting Description
Factory
Default
Max. 31
Characters
A string identifying the user name that this entry should belong to.
The allowed string length is 1 to 31. The valid user name allows
letters, numbers
,
and underscores.
None
Password
Setting Description
Factory
Default
Max. 31
Characters
The password of the user. The allowed string length is 0 to 31. Any
printable characters including space is accepted.
None
Privilege Level
Setting Description
Factory
Default
0~15
The privilege level of the user. The allowed range is 0 to 15. If the
privilege level value is 15, it can access all groups, i.e. that is granted
the full control of the device. But other values need to refer to each
group privilege level. User’s privilege should be the same or greater
than the group privilege level to have the access of that group. By
default setting, most group’s privilege level 5 has the read-only
access and privilege level 10 has the read-write access. And the
system maintenance (software upload, factory defaults, etc.) requires
user privilege level 15. Generally, the privilege level 15 can be used
for an administrator account, privilege level 10 for a standard user
account, and privilege level 5 for a guest account.
0