Maintenance > Factory Defaults
Factory Defaults
You can reset the configuration of the switch on this page. Only the IP configuration is retained. The
new configuration is available immediately which means that no restart is necessary.
Click Yes to reset the configuration to Factory Defaults.
Click No to return to the Port State page without resetting the configuration.
NOTE: Restoring factory default can also be performed by making a physical loopback between port
1 and port 2 within the first minute from switch reboot. In the first minute after boot, loopback
packets will be transmitted at port 1. If a loopback packet is received at port 2, the switch will do a
restore to default.
.