Application Guide
[217]
Software User's
Manual
–
Version 3.0
Port Configuration
Setting Description
Port The port number for which the configuration below applies.
Flow Sampler
Enabled
Enables/disables flow sampling on this port.
Flow Sampler
Sampling Rate
The statistical sampling rate for packet sampling.
Set to N to sample on average 1/Nth of the packets transmitted/received on
the port. Not all sampling rates are achievable.
If an unsupported sampling rate is requested, the switch will automatically
adjust it to the closest achievable. This will be reported back in this field.
Valid rang
e is 1 to 4294967295.
Flow Sampler Max.
Header
The maximum number of bytes that should be copied from a sampled
packet to the sFlow datagram.
Valid range is 14 to 200 bytes with default being 128 bytes. If the maximum
datagram size does not take into account the maximum header size,
samples may be dropped.
Counter Poller
Enabled
Enables/disables counter polling on this port.
Counter Poller
Interval
With counter polling enabled, this specifies the interval - in seconds -
between counter poller samples.
Valid range is 1 to 3600 seconds.