Application Guide
[216]
Software User's
Manual
–
Version 3.0
If sFlow is configured through SNMP, all controls - except for the Release-button - are disabled to
avoid inadvertent reconfiguration.
The “Release” button allows for releasing the current owner and disable sFlow sampling. The button
is disabled if sFlow is currently unclaimed. If configured through SNMP, the release must be confirmed
(a confirmation request will appear).
IP Address/Hostname
Setting Description
Factory
Default
IP Address
The IP address or hostname of the sFlow receiver. Both IPv4 and IPv6
addresses are supported.
0.0.0.0
UDP Port
Setting Description
Factory
Default
port
number
The UDP port on which the sFlow receiver listens to sFlow datagrams. 6343
Timeout
Setting Description
Factory
Default
0 ~ 2147483647
The number of seconds remaining before sampling stops and the
current sFlow owner is released. While active, the current time left
can be updated with a click on the Refresh-button. If locally
managed, the timeout can be changed on the fly without affecting
any other settings.
Valid range is 0 to 2147483647 seconds.
0
Max. Datagram Size
Setting Description
Factory
Default
200 ~ 1468
The maximum number of data bytes that can be sent in a single sample
datagram. This should be set to a value that avoids fragmentation of
the sFlow datagrams. Valid range is 200 to 1468 bytes.
1400