Application Guide

[206]
Software User's
Manual
Version 3.0
PCP
Priority Code Point: Valid values of PCP are specific (0, 1, 2, 3, 4, 5, 6, 7) or a
range
(0
-
1, 2
-
3, 4
-
5, 6
-
7, 0
-
3, 4
-
7) or 'Any'.
DEI Drop Eligible Indicator: Valid value of DEI are 0, 1 or 'Any'.
Frame Type
Indicates the type of frame. Possible values are:
1. Any: Match any frame type.
2. Ethernet: Match EtherType frames.
3. LLC: Match (LLC) frames.
4. SNAP: Match (SNAP) frames.
5. IPv4: Match IPv4 frames.
6. IPv6: Match IPv6 frames.
Action
Indicates the classification action taken on ingress frame if parameters
configured are matched with the frame's content.
Possible actions are:
1. CoS: Classify Class of Service.
2. DPL: Classify Drop Precedence Level.
3. DSCP: Classify Differentiated Services Code Point value.
4. PCP: Classify Priority Code Point value.
5. DEI: Classify Drop Eligible Indicator value.
6. Policy: Classify ACL Policy number.
QCE Configuration
This page allows the user to edit / insert a single QoS Control Entry at a time. A QCE consists of
several parameters. These parameters vary according to the frame type that you select.