Application Guide

[171]
Software User's
Manual
Version 3.0
Delay Measurement Bins for FD
A Measurement Bin is a counter that stores the number of delay measurements falling within a
specified range during a Measurement Interval.
Below is the following example: if the measurement threshold is 5000 us and the total number of
Measurement Bins is four.
Bin Threshold Range
bin0 0 us 0 us <= measurement < 5,000 us
bin1 5,000 us 5,000 us <= measurement < 10,000 us
bin2 10,000 us 10,000 us <= measurement < 15,000 us
bin3 15,000 us
Delay Measurement Bins for IFDV
A Measurement Bin is a counter that stores the number of delay measurements falling within a
specified range during a Measurement Interval.
Below is the following example: if the measurement threshold is 5000 us and the total number of
Measurement Bins is four.
Bin Threshold Range
bin0 0 us 0 us <= measurement < 5,000 us
bin1 5,000 us 5,000 us <= measurement < 10,000 us
bin2 10,000 us 10,000 us <= measurement < 15,000 us
bin3 15,000 us