Application Guide
[170]
Software User's
Manual
–
Version 3.0
Delay Measurement Bins
A Measurement Bin is a counter that stores the number of delay measurements falling within a
specified range during a Measurement Interval.
Setting Description
Measurement
Bins for FD
Configurable number of Frame Delay Measurement Bins per Measurement
Interval.
The minimum number of FD Measurement Bins per Measurement Interval
supported is 2.
The maximum number of FD Measurement Bins per Measurement Interval
supported is 10.
The default number of FD Measurement Bins per Measurement Interval
supported is 3.
Measurement
Bins for IFDV
Configurable number of Inter-Frame Delay Variation Measurement Bins per
Measurement Interval.
The minimum number of FD Measurement Bins per Measurement Interval
supported is 2.
The maximum number of FD Measurement Bins per Measurement Interval
supported is 10.
The default number of FD Measurement Bins per Measurement Interval
supported is 2.
Measurement
Threshold
Configurable the Measurement Threshold for each Measurement Bin.
The unit for a measurement threshold is in microseconds (us).
The default configured measurement threshold for a Measurement Bin is an
increment of 5000 us.