Application Guide
[167]
Software User's
Manual
–
Version 3.0
Consecutive
Interval
High Loss Interval consecutive interval (number of measurements).
Loss Measurement High Loss Interval Status
Setting Description
Near Count
Near end high loss interval count - number of measurements where
availability state is available and FLR is above high loss interval FLR
threshold.
Far Count
Far end high loss interval count - number of measurements where
availability state is available and FLR is above high loss interval FLR
threshold.
Near Consecutive
Count
Near end high loss interval consecutive count.
Far Consecutive
Count
Far end high loss interval consecutive count.
Loss Measurement Signal Degrade
Setting Description
Enable Enable/disable of loss measurement signal degrade.
TX Minimum
Minimum number of frames that must be transmitted in a measurement
before frame loss ratio is tested against loss ratio threshold.
FLR Threshold Signal Degraded frame loss ratio threshold in per mille.
Bad Threshold
Number of consecutive bad interval measurements required to set degrade
stat
e.
Good Threshold
Number of consecutive good interval measurements required to clear
degrade state.