Tx Reinit
Setting Description
Factory
Default
1 ~ 10
When an interface is disabled, LLDP is disabled, or the switch is
rebooted; an LLDP shutdown frame is transmitted to the neighboring
units, signaling that the LLDP information isn’t valid anymore. Tx
Reinit controls the number of seconds between the shutdown frame
and a new LLDP initialization. Valid values are restricted to 1
- 10 seconds.
2
LLDP Interface Configuration
Setting Description
Interface The switch interface name of the logical LLDP interface.
Mode
Select LLDP mode.
Rx only: The switch will not send out LLDP information, but LLDP information
from neighbor units is analyzed.
Tx only: The switch will drop LLDP information received from neighbors, but will
send out LLDP information.
Disabled: The switch will not send out LLDP information and will drop LLDP
information received from neighbors.
Enabled: The switch will send out LLDP information and will analyze LLDP
information received from neighbors.