Application Guide
[89]
Software User's
Manual
–
Version 3.0
TCP/UDP Source Range
Setting Description
Factory
Default
0 ~ 65535
When Range is selected for the TCP/UDP source filter, you can
enter a specific TCP/UDP source range value. The allowed range
is 0 to 65535. A frame that hits this ACE matches this TCP/UDP
source value.
0
TCP/UDP Destination Filter
Setting Description
Factory
Default
Any No TCP/UDP destination filter is specified
Any
Specific
If you want to filter a specific TCP/UDP destination filter with this
ACE, you can enter a specific TCP/UDP destination value. A field
for entering a TCP/UDP destination value
appears.
Range
If you want to filter a specific range TCP/UDP destination filter with
this ACE, you can enter a specific TCP/UDP destination range
value. A field for entering a TCP/UDP destination value appears.
TCP/UDP Destination Number
Setting Description
Factory
Default
0 ~ 65535
When Specific is selected for the TCP/UDP destination filter, you
can enter a specific TCP/UDP destination value. The allowed range
is 0 to 65535. A frame that hits this ACE matches this TCP/UDP
destination value.
0
TCP/UDP Destination Range
Setting Description
Factory
Default
0 ~ 65535
When Range is selected for the TCP/UDP destination filter, you can
enter a specific TCP/UDP destination range value. The allowed
range is 0 to 65535. A frame that hits this ACE matches this
TCP/UDP destination value.
0
TCP FIN
Specify the TCP "No more data from sender" (FIN) value for this ACE.
Setting Description
Factory
Default
0
TCP frames where the FIN field is set must not be able to match this
entry.
Any
1 TCP frames where the FIN field is set must be able to match this entry.
Any Any value is allowed.