6
without changing the straight-through or crossover cabling. See the figures as below for straight-
through and crossover cabling schematics.
RJ-45 Pin Assignments (Table 2.2)
Pin Number Assignment
1 Rx+
2 Rx-
3 Tx+
6 Tx-
All ports on this industrial Ethernet switch support automatic MDI/MDI-X operation. Users can
use straight-through cables (see figure below) for all network connections to PCs, servers, other
switches or hubs. With straight-through cable pins 1, 2, 3, and 6, at one end of the cable are
connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below
(Table 2.3) shows the 10BASE-T/100BASE-TX MDI and MDI-X port pin outs.
The following figures show the cabling schematics for straight-through and crossover.
Figure 2.4 Figure 2.5
Straight-Through Cable Schematic Crossover Cable Schematic
Note
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
Pin MDI-X Signal Name MDI Signal Name
1 Receive Data plus (RD+) Transmit Data plus (TD+)
2 Receive Data minus (RD-) Transmit Data minus (TD-)
3 Transmit Data plus (TD+) Receive Data plus (RD+)
6 Transmit Data minus (TD-) Receive Data minus (RD-)
Table 2.2
RJ45 Pin Assignments