Instruction manual
Instruction Manual8
The battery is on the cyclic process of charge and discharge and can 
often become warm after charge of discharge period. The program 
can insert a time delay to occur after each charge and discharge 
process, to allow the battery adequate time to cool down before being 
subjected to the next process. The value ranges from 1 to 60 minutes.
You can set the trickle charge mode on or off. If it is on, the charger 
will automatically supply the trickle charge current to achieve the full 
charge without overheating the battery after fast charge has been 
terminated.
When you start a charge process, the integral safety timer 
automatically starts running at the same time. This is programmed 
to prevent overcharge the battery, if it proves to be faulty, or if the 
termination circuit cannot detect the battery full. The value for the 
safety timer should be generous enough to allow a full charge of the 
battery.
This program sets the maximum charge capacity that will be supplied 
to the battery during charge. If the delta-peak voltage is not detected 
nor the safety timer expired by any reason, this feature will 
automatically stop the process at the selected capacity value.
The beep sounds at every time pressing the buttons to confirm your 
action. The beep or melody sounds at various times during operation 
to alert different mode changes. There audible sounds can be on or 
off.
This program monitors the voltage of input battery. If the voltage 
drops below the value you set, the operation forcibly will be 
terminated to protect the input battery.
Yon can adjust the brightness of LCD screen at the charger.