Instruction manual
 Balance Charger xMove 2.0 Deluxe 19
24.  Warning and Error Messages
xMove 2.0 Deluxe incorporates various functions of protective and 
monitoring the system to verify functions and the state of its 
electronics. In any case of occurring an error, the screen displays the 
cause of error that is self-explanatory with audible sound. 
The output is connected to a battery with incorrect polarity.
This will be displayed in case of detecting an interruption of the 
connection between battery and output or voluntarily disconnecting 
the charge lead during the operation of charge of discharge on 
output.
There was a short-circuit at OUTPUT. Please check the charging leads.
The voltage of input power drops below the limit.
The voltage of Lithium battery pack was selected incorrectly. Verify 
the voltage of battery pack carefully.
There happens the malfunction at the charger circuit by any reason.
The processor detects the voltage is lower than you set at Lithium 
program. Please check the cell count of the battery pack.
The processor detects the voltage is higher than you set at Lithium 
program. Please check the cell count of the battery pack.
The voltage of one of the cell in the Lithium battery pack is too low. 
Please check the voltage of the cell one by one. 
The voltage of one of the cell in the Lithium battery pack is too high. 
Please check the voltage of the cell one by one. 
There are bad connections at the individual connector. Please check 
the connector and cables carefully.
The internal temperature of the unit goes too high. Cool down. 
The processor can not continue to control the feeding current by and 
reason. The unit needs to be repaired.










