Datasheet
Conditions
 cell type: NiMH
 cell size: AA
 nominal voltage: 1.2 V
 max. charge voltage: 1.5 V at standard charge
(0.1C / 20°C)
 capacity
 nominal: 2000 mAh discharge at 0.2C
 minimum: 1900 mAh discharge at 0.2C
1800 mAh discharge at 1C
1.0V end discharge voltage
ta: 20°C
 max. continuous
 discharge current: 4000 mA ta: 0....45°C
 charge current time
 standard charge: 200 mA 14....16hrs
 quick charge: 575 mA 4hrs
 fast charge: 2000 mA 1.1hrs
 recommended charge  0…5 mV - ΔV (-deltaV)
 termination control 0.8...1 °C temperature rise per minute
 parameters: 45...50 °C TCO (temperature cut off)
 trickle charge current:
10…40 mA (recommended)
 continuous overcharge: ≤ 200 mA no conspicuous deformation
 (less than 1 year) no leakage
 internal resistance: ≤ 35 mΩ at 1KHz
 (impedance) battery fully charged
 life expectance: ≥ 1500 cycles acc. IEC standard
 self discharge
 charge retention: ≥ 80 % after 12 months
storage at 20°C
 initial capacity: ≥ 1400 mAh within 30 days after delivery
discharge at 0.2C to 1.0V
 ambient temperature
 range:  0...45 °C standard charge
0...40 °C fast charge
 0...50 °C discharge
- 20...50 °C storage (≤3months)
- 20...40 °C storage (≤6months)
- 20...30 °C storage (≤24months)
 QCT1: 20/1850/35
 QCT2: 30/1750/35
 mechanical specifications
 cell dimensions (with tube)
 diameter d1: 14.4 - 0.5 mm
 diameter d2: max. 5.5 mm
 height h1: 50.5 - 0.5 mm
 height h2: min. 1.2 mm
 weight: 27 ± 2 g
 batterybox dimensions
 depht d3: 67 mm
 width w1: 55 mm
 hight h3: 22 mm
 weight: 12 g
 total weight: 120 ± 8 g
16
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice
 ANSMANN Specifications for model:
 data sheet no. / part no.
 supplier no.
 author / date
Ansmann maxE PRO AA - 2000mAh 
RTU battery 4pcs box
1302-0013-1
703642
AC / 03.02.2015
Diagrams
standard charge
fast charge
low rate discharge
high rate discharge