Displaying Relative Power
Step 21.
Press the AMPLITUDE key.
Step 22. With the desired base power level input to the sensor, press the
Rel soft key. The
message area will show
Relative On and the power reading will show 0 dB and
100%. If measuring a 10 dBm signal with the
Rel key selected, a drop to 7 dBm
will show –3dB and 50%.
Saving the Measurement
Step 23.
Press the SAVE DISPLAY key.
Step 24. Use the soft keys to enter a Trace Name.
Transferring Data to Handheld Software Tools
The Site Master has only one serial port, so it is not possible to communicate with both the
PSN50 sensor and a PC running Handheld Software Tools (HHST) at the same time. There-
fore, only saved measurements can be viewed in HHST when using the PSN50. To view
saved measurements, disconnect the serial cable from the PSN50 and connect it to the serial
port of the PC running HHST. Refer to the Handheld Software Tools chapter in this manual
for further information.
6-4