Specifications
46 Product Brochure
l
MX3701xxA
MX370110A LTE TDD IQproducer
Optional
● PHY/MAC Parameter (Uplink) Setting Range
Display Outline Setting Range
Uplink
delta PUCCH shift Sets delta PUCCH shift 1, 2, 3
N_CS(1)
Sets number of cyclic shift for PUCCH
format 1/1a/1b
0 to 7
N_RB(2)
Sets number of resource block for PUCCH
format 2/2a/2b
0 to 63
Subframe #0 to #9
Subframe Type Display subframe type <Table 1> (Downlink, Uplink, Special)
Number of PUCCHs Sets number of PUCCHs 0 to 8
Number of PUSCHs Sets number of PUSCHs 0 to 8
PUCCH #0 to #7
Data Status Enables/disables PUCCH parameter Disable, Enable
n(1)_PUCCH Sets resource number of PUCCH 1/1a/1b 0 to 764
n(2)_PUCCH Sets resource number of PUCCH 2/2a/2b 0 to 764
nRNTI Sets radio network temporary identier 0000 to FFFF
PUCCH format Sets PUCCH format 1, 1a, 1b, 2, 2a, 2b
Data Type Sets data type PN9x, PN15x, 16 bit repeat, User File, UCI
Data Type Repeat Data Sets 16 bit repeat data 0000 to FFFF (only when Data Type = 16 bit repeat)
Data Type User File Sets user le Select any le (only when Data Type = User File).
Group Hopping Sets enable/disables Disable, Enable
Base Sequence Group Number u Sets base sequence group number 0 to 29
Base Sequence Number v Displays base sequence group number 0 xed
Power Boosting Sets power boosting –20.000 to +20.000 dB
UCI
Transport Block Size Sets transport block size of UCI
1 (When PUCCH format = 1a)
2 (When PUCCH format = 1b)
1 to 13 (When PUCCH format = 2)
2 to 14 (When PUCCH format = 2a)
3 to 15 (When PUCCH format = 2b)
Data Type Sets data type PN9x, PN15x, 16 bit repeat, User File
Data Type Repeat Data Sets 16 bit repeat data 0000 to FFFF (only when Data Type = 16 bit repeat)
Data Type User File Sets user le Select any le (only when Data Type = User File).
Demodulation RS for PUCCH
Group Hopping Sets enable/disables Disable, Enable
Base Sequence Group Number u Sets base sequence group number 0 to 29
Base Sequence Number v Displays base sequence group number 0 xed
PUSCH #0 to #7
Data Status Enables/disables PUSCH parameter Disable, Enable
nRNTI Sets radio network temporary identier 0000 to FFFF
Modulation Scheme Modulation system QPSK, 16QAM, 64QAM
Data Type Sets data type PN9x, PN15x, 16 bit repeat, User File, UL-SCH
Data Type Repeat Data Sets 16 bit repeat data 0000 to FFFF (only when Data Type = 16 bit repeat)
Data Type User File Sets user le Select any le (only when Data Type = User File).
Start Number of RB Start position of RB
0 to 5 (When Bandwidth = 1.4 MHz)
0 to 14 (When Bandwidth = 3 MHz)
0 to 24 (When Bandwidth = 5 MHz)
0 to 49 (When Bandwidth = 10 MHz)
0 to 74 (When Bandwidth = 15 MHz)
0 to 99 (When Bandwidth = 20 MHz)
Number of RBs Total number of RB
1 to 6 (When Bandwidth = 1.4 MHz)
1 to 15 (When Bandwidth = 3 MHz)
1 to 25 (When Bandwidth = 5 MHz)
1 to 50 (When Bandwidth = 10 MHz)
1 to 75 (When Bandwidth = 15 MHz)
1 to 100 (When Bandwidth = 20 MHz)
Power Boosting Set power boosting –20.000 to +20.000 dB
UL-SCH
Transport Block Size Sets transport block size of UL-SCH 0 to 86400
Data Type Sets data type PN9x, PN15x, 16 bit repeat, User File
Data Type Repeat Data Sets 16 bit repeat data 0000 to FFFF (only when Data Type = 16 bit repeat)
Data Type User File Sets user le Select any le (only when Data Type = User File).
RV Index Sets redundancy version index 0, 1, 2, 3
Demodulation RS for PUSCH
Group Hopping Sets enable/disables Disable, Enable
Sequence Hopping Sets enable/disables Disable, Enable
Delta ss Sets delta ss 0 to 29
Base Sequence Group Number u Sets base sequence group number 0 to 29
Base Sequence Number v Displays base sequence group number 0, 1
Cyclic Shift 1st slot
n_cs Sets ncs of rst slot of demodulation RS 0 to 11
alpha
Sets cyclic shift of rst slot of demodulation
RS
Alpha is calculated by the following expression.
Five digits below the decimal are displayed.
alpha = 2×pi×n_cs/12
Cyclic Shift 2nd slot
n_cs
Sets ncs of second slot of demodulation RS
0 to 11
alpha
Sets cyclic shift of second slot of
demodulation RS
Alpha is calculated by the following expression.
Five digits below the decimal are displayed.
alpha = 2×pi×n_cs/12
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com