User Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Network Connection
- Chapter 3 Accessing to the Network Speed Dome
- Chapter 4 Basic Operations
- Chapter 5 System Configuration
- 5.1 Storage Settings
- 5.2 Basic Event Configuration
- 5.3 Smart Event Configuration
- 5.3.1 Configuring Intrusion
- 5.3.2 Configuring Line Crossing Detection
- 5.3.3 Configuring Region Entrance Detection
- 5.3.4 Configuring Region Exiting Detection
- 5.3.5 Configuring Unattended Baggage Detection
- 5.3.6 Configuring Object Removal Detection
- 5.3.7 Configuring Face Detection
- 5.3.8 Configuring Audio Exception Detection
- 5.4 PTZ Configuration
- Chapter 6 Speed Dome Configuration
- Appendix
User Manual of Network Speed Dome
46
Figure 5-20 Configuring Unattended Baggage Detection
2. Check Enable.
3. Select the Region from the drop-down list for detection settings.
4. Click Area Settings and click Draw Area to start the area drawing.
5. Click on the live video to specify the four vertexes of the detection region, and right click to
complete drawing.
6. Click Stop Drawing when finish drawing.
7. Set the time threshold and detection sensitivity for unattended baggage detection.
Threshold: Range [5-100s], the threshold for the time of the objects left over in the region. If
you set the value as 10, alarm is triggered after the object is left and stay in the region for
10s.
8. Drag the slider to set the sensitivity value.
Sensitivity: Range [1-100]. Sensitivity stands for the percentage of the body part of an
acceptable target that enters the pre-defined region.
Sensitivity = 100 – S
1
/S
T
*100
S
1
stands for target body part that enters the pre-defined region. S
T
stands for the complete
target body.
Example: if you set the value as 60, a target is possible to be counted as an unattended
baggage only when 40 percent body part of the target enters the region.