Installation Sheet
© 2018 ANP Lighting. All rights reserved. These specications are intended for general purposes only.
ANP reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products.
1-800-548-3227
ANPlighting.com
M + D CORD MOUNT INSTALLATION INSTRUCTIONS
05172018
Standard 4/0 Junction Box
(by others)
Ground Wire
Nipple (D)
Jam Nut (E)
Cord Clamp (G)
Hanger Bracket (F)
Canopy (C)
Bushing (B)
Cord (A)
3/4” Minimum
Approximately 3/4”
RTC Cover Plate (B)
Arm (A)
Set Screws (C)
Screws (E)
RTC Box (D)
RTC Cover Plate (B)
Arm (A)
Set Screws (C)
Screws (D)
Standard 4/0 Junction Box
(by others)
Prior to installation, disconnect power
at main electrical box.
Thread nipple (D)/jam nut (E) into strap
as shown, allowing approximately 3/4”
below strap. Tighten jam nut.
Pull cord (A) through bushing (B), canopy
(C), nipple (D)/jam nut (E)/hanger bracket
(F) as shown.
Pull cord thru hanger bracket to adjust
height, position cord clamp (G) with
ange down, near nipple and use pliers
to tightly crimp the cord clamp.
Hold bracket to canopy to check xture
height.
Cut wires to provide 6” pigtail with junc-
tion box. Jacket can be cut back to 3/4”
from clamp.
Make power and ground wiring connec-
tions.
Slip canopy over nipple and secure with
bushing. Adjust nipple as needed so
canopy is ush to ceiling.
1.
2.
3.
4.
5.
6.
7.
8.
Cord Mount
IMPORTANT
Safety, Warning and Suggestions
1. Qualied electrician is required to install this product/s.
2. Please read instructions carefully before installation.
3. All wiring and installations should meet local, state and national electrical codes.
4. Install correct lamp type and wattage.