User Manual

Eminere Inground
6
Note: the cabel (11) of the Eminere Inground is 2 m long, we recommend to shorten the cable on 1 m.
The supply/data cable to and from the mounting sleeve must be placed in a protective tube (12).
6. After connecting cables to the junction box (8), screw the Eminere Inground (13) to the mounting sleeve (1)
by means of the countersunk- allen head bolts M5x25 (14). The screws (14) must be tightened smoothly
with torque of 4Nm. Do not use impact wrench.
7. Screw the cover plates (15), (22) on the mounting sleeve (1) by means of the six countersunk- allen head
bolts M5x30 (16). The crews (16) must be tightened smoothly with torque of 4Nm. Do not use impact
wrench.
Junnction box
The Eminere Inground is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 120-277 Volts.
The Emineres Inground should be connected to the E-box (E-box Daisy/E-box Star/E-box Pro/E-box Lite) which
allows power supply of the Emineres Inground and their control.
Do not connect (disconnect) Emineres Inground to the E-box and each other when they are under voltage!
When you change any setting of the E-box, disconnect the E-box from power and connect it to power again
to activate changes which you have made.
1. Unscrew the four screws M4x20 (17) on the cover of the junction box and remove this cover (18) with
gasket (19) to get access to the connection block (20).