QR code for user manual Version 1.
Eminere Inground Table of contents 1. Safety instructions ......................................................................................................................................................3 2. Fixture exterior view ................................................................................................................................................... 4 3. Installation ..............................................................................................................
Eminere Inground FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
Eminere Inground Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity. The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
Eminere Inground 3.1 Mounting the Eminere Inground Warning! If the Eminere Inground will be exposed to max. allowed static load, the subsoil under the installation sleeve has to withstand load of: 45kN (standard covering glass) 23kN (antiskid covering glass). Example of installation of the Eminere Inground 2 1. Prepare an adequate hole with a good drainage leaving at least 300 mm of gravel on the bottom of the hole for inserting the mounting sleeve (1) into the prepared hole.
Eminere Inground Note: the cabel (11) of the Eminere Inground is 2 m long, we recommend to shorten the cable on 1 m. The supply/data cable to and from the mounting sleeve must be placed in a protective tube (12). 6. After connecting cables to the junction box (8), screw the Eminere Inground (13) to the mounting sleeve (1) by means of the countersunk- allen head bolts M5x25 (14). The screws (14) must be tightened smoothly with torque of 4Nm. Do not use impact wrench. 7.
Eminere Inground 2. Connect cables to the junction box (20).
Eminere Inground We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body in case that you need to unscrew and remove the cable gland from the housing of the junction box and and screw it back to the housing. Remove end caps from cable glands before passing cables into the junction box.
Eminere Inground Junction box filled with resin. Earth wire 4. Screw the cover (18) with gasket (19) to the junction box by means of the four screws (17) and check they are fully tighten. 8. If you install two or more Emineres Inground side by side, you have to screw three types of the cover plates: end (15), middle (23) and continuous (22).
Eminere Inground Note: If the Emineres Inground are installed in a loose soil (e.g. sand, gravel) the cover plate support (25) has to be fastened under the cover plate at outer (end) Eminere Inground. Screw the cover plate support (25) on the outside of the Eminere Inground by means of two screws Allen bolts M5x10 with washers and nuts M5.
Eminere Inground 9. Tilt adjustment. The Eminere Inground can be tilted by +/-15° after installing it in the mounting sleeve. Push and hold the small tube (24) to release the lock of the Eminere Inground and tilt the device to desired position. Release the small tube (24) to lock the new position of the Eminere Inground. Use E-boxes ( E-box Daisy, E-box Star, E-box Pro, E-box Lite) to control Emineres Inground. Please read the E-boxes user manual for more information about their setting.
Eminere Inground Eminere Inground 4 * Voltage Cable length * 120V 190V 230V 277V 10 m 21 32 32 32 20 m 21 32 32 32 30 m 15 32 32 32 50 m 9 22 32 32 70 m 6 16 23 32 100 m 4 11 16 23 Cable length is a total cable length between E-box and last connected Eminere. Example of connection: E-box Daisy Total cable length= L1+∑L2+∑L3. Max. total cable length between one LED output of the E-box and last connected Eminere Inground must not exceed 100m.
Eminere Inground 4.
Eminere Inground • E-box Lite 1 output 1 Main power Input Control: DMX, W-DMX control, RDM Pixel control (1px= 1ft) 120-277V Input Connection via screw terminal blocks, inlets via grommet IP67 Mounting method • Inground mount Adjustability • +/- 15° after instalation Housing • High pressure extruded aluminium body • End caps - Die-Cast Aluminium • Welded instalation sleeve for pre-instalation • Tempered glass Cooling system • Convection Total heat dissipation • Eminere Inground 2: 130 BTU/h (calculated) • E
Eminere Inground Dimensions (All dimensions in mm [inch]) • Eminere Inground 2/Eminere Inground 4 Dimensions with mounting sleeve (All dimensions in mm [inch]) • Eminere Inground 2/Eminere Inground 4 15
Eminere Inground Included items • 1 x Eminere Inground • 1 x mounting sleeve • 1 x User manual Optional accessories P/N 10980506 Eminere Inground 2 Mounting Sleeve P/N 10980508 Eminere Inground 2 cover plate continuous P/N 10980539 Eminere Inground 4 Mounting Sleeve P/N 10980526 Eminere Inground 4 cover plate continuous P/N 10980509 Eminere Inground cover plate end P/N 10063655 E-box Daisy P/N 10063638 E-box Daisy/W P/N 10063657 E-box Lite P/N 10063653 E-box Lite/W P/N 10063656 E-box Star P/N 10063644 E-box
Eminere Inground 6. ChangeLog This section summarizes changes in the user manual. Version of the manual Date of issue Description of changes 1.1 09/07/2020 Voltage range change 1.2 30/09/2020 Static load changed 1.3 08/01/2020 Cover plates changed 1.4 03/09/2021 Torques for plate cover screws added 1.5 19/10/2021 Technical specifications changed 1.6 26/11/2021 Optional accessories changed 1.7 08/03/2022 Screw lengths changed 1.