Eminere Wireless DMX Table of contents 1. Safety instructions ......................................................................................................................................................3 2. Fixture exterior view ................................................................................................................................................... 4 3. Installation ..........................................................................................................
Eminere Wireless DMX FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
Eminere Wireless DMX The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance. Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Most damages are the result of unprofessional operation! Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility.
Eminere Wireless DMX 3. Installation 3.1 Mounting the fixture The Eminere can be arranged in any orientation on a flat, non-flammable surface by means of two mounting brackets (5), the LED module (2) can be tilted (+95°/-95°) to get access to mounting brackets (5). Ensure that the structure to which you are attaching the unit is secure. 3.2 Connection to mains The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Eminere Wireless DMX The output panel connector at last fixture in the Emineres chain has to always be covered with the water-tight cap to keep declared IP rating. Do not connect (disconnect) Emineres to the Booster box and each other when they are under voltage! Direct visibility between a transmitter and the Eminere Wireless DMX must be ensured without no obstacles (bildings, trees,....).
Eminere Wireless DMX 50 m 17 32 32 32 70 m 12 31 32 32 100 m 9 21 32 32 EMINERE 3 wireless DMX Voltage Cable length * 120V 190V 230V 277V 10 m 28 32 32 32 20 m 28 32 32 32 30 m 19 32 32 32 50 m 12 29 32 32 70 m 8 21 31 32 100 m 6 15 21 31 EMINERE 4 wireless DMX Voltage Cable length * 120V 190V 230V 277V 10 m 21 32 32 32 20 m 21 32 32 32 30 m 15 32 32 32 50 m 9 22 32 32 70 m 6 16 23 32 100 m 4 11 16 23 * Cable length is
Eminere Wireless DMX 20 m - - - - 30 m 28 - - - 50 m 17 - - - 70 m 12,24, 31 - - 100 m 9,18 21 31 EMINERE 3 Wireless DMX Max. possible number of Emineres 3 Wireless DMX = 32 Voltage Cable length 120V 190V 230V 277V 10 m 28 - - - 20 m 28 - - - 30 m 19 - - - 50 m 12,24 29 - - 70 m 8,16,24 21 31. - 100 m 6,12,18,24,30 15,30 21 31 EMINERE 4 Wireless DMX Max.
Eminere Wireless DMX 3.4 The Booster box installation ALWAYS DISCONNECT THE EMINERES FROM MAINS BEFORE CONNECTING/DISCONNECTING THE BOOSTER BOX. The Booster box falls under protection class I. Therefore, every Booster box has to be connected to a mains socket outlet with a protective earthing connection. 1.Unscrew the four screws (1) from the cover (2) on the Booster box to get access to the terminal block (3) and two mounting holes of diameter of 4.6 mm (4). 2.
Eminere Wireless DMX Cable gland M20 MS: The cable gland M20 MS with a standard seal serves for a cable of diameter of 6-12mm, for smaller diameter of cable (4-8mm) you have to remove the original seal from the cable gland M20 and use the enclosed reducing seal instead of it. The reducing seal for diameter of cable 4-8mm (P/N 13051388) is enclosed in the Booster box. 3. Screw the cover (2) back on the Booster box.
Eminere Wireless DMX 3.5 Jumper cable assembling 1. Dismantle the connector and slide its parts onto the cable (6). Use the seal with inner diameter of 14.5 mm for the Anolis cable (P/N 13053138 or P/N 13053139). The seal with inner diameter of 14.5 mm serves for cable of diameter 10-14.5mm. The seal with inner diameter of 10 mm serves for cable of diameter 8-10mm. Parts of the connector Detail of Sealing circle (2) placing 2. Put the seiling circle (2) on the connector with screws (1). 3.
Eminere Wireless DMX US version 4. Put parts of the connector on the cable (6) and connect wires to the connector. First connect power wires (L,N, Earth) and after that data wires (D+, D-, 0V).
Eminere Wireless DMX 5. After connecting wires to the connector, tighten the three data wires (D+,D-, 0V) by means of the cable binder (7). 6. Screw the clamp ring (3) to the connector (1), insert the seal (4) to the clamp ring (3) and tighten the sealing nut (5) enough. During the steps DO NOT TWIST the cable (6). 7. Use the same procedure to assemble the connector on the second end of the cable. IMPORTANT Do not bend the cable near to the connector, minimum distance for bending is 50mm.
Eminere Wireless DMX 4.
Eminere Wireless DMX Operating ambient temperature range • -20°C /+40°C (-4°F /+104°F) Operating temperature • +67°C @ Ambient +40°C (+153°F @ Ambient +104°F) Connection Weight • Input: panel connector Amphenol ABAB-DMQ06000021-IN (P/N13052952) • Output: panel connector Amphenol ABAB-DAQ06000021 (P/N13052953) + water-tight cap •Eminere 2: 4 kg (8.82 lbs) •Eminere 3: 6.02 kg (13.27 lbs) •Eminere 4: 7.
Eminere Wireless DMX • Booster box Included items • 1 x Eminere • 1 x User manual Optional accessories Jumper Cables FF/FM: Jumper Cable FF/FM 0,25m (P/N 13053052) Jumper Cable FF/FM 0,5m (P/N 13053053) Jumper Cable FF/FM 1m (P/N 13053054) Jumper Cable FF/FM 2m (P/N 13053055) Jumper Cable FF/FM 3m (P/N 13053056) Jumper Cable FF/FM 5m (P/N 13053057) Jumper Cable FF/FM 10m (P/N 13053058) Waterproof Cover Cap FM ZAHB-0006 (P/N 17031173) Field Installable Connector FF (P/N 13053003) Field Installable Connector
Eminere Wireless DMX Cable Cover for Eminere 2 RAL9011 (P/N 10980485) Cable Cover for Eminere 3 RAL9011 (P/N 10980486) Cable Cover for Eminere 4 RAL9011 (P/N 10980487) Shield for Eminere 2 RAL9011 (P/N 10980489) Shield for Eminere 3 RAL9011 (P/N 10980490) Shield for Eminere 4 RAL9011 (P/N 10980491) Mounting Brackets for Eminere 100mm, 2pcs RAL9011 (P/N 10980493) Mounting Brackets for Eminere 200mm, 2pcs RAL9006 (P/N 10980529) Mounting Brackets for Eminere 200mm, 2pcs RAL9011 (P/N 10980494) Mounting Brackets