Version 2.
Eminere Table of contents 1. Safety instructions ......................................................................................................................................................3 2. Fixture exterior view ................................................................................................................................................... 4 3. Installation .......................................................................................................................
Eminere FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
Eminere The fixture becomes hot during operation. Allow the fixture to cool approximately 30 minutes prior to servicing or maintenance. Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Most damages are the result of unprofessional operation! Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility.
Eminere 3. Installation 3.1 Mounting the fixture The Eminere can be arranged in any orientation on a flat, non-flammable surface by means of two mounting brackets (5), the LED module (2) can be tilted (+95°/-95°) to get access to mounting brackets (5). Ensure that the structure to which you are attaching the unit is secure. 3.2 Connection to mains The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
Eminere The output panel connector at last fixture in the Eminere chain has to always be covered with the water-tight cap to keep declared IP rating. The Eminere modules should be connected to the E-box which allows power supply of the Eminere modules and their control.
Eminere E-box Pro E-box Lite 7
Eminere Number of connected Emineres to one E-box output depends on a cable length, power voltage, type of Eminere and E-box and operation mode. The tables below state max. theoretical number of Emineres connected to the one LED output of the E-box without Booster boxes. The following tables apply for the Standard mode of E-boxes.
Eminere EMINERE 4 Voltage Cable length * 120V 190V 230V 277V 10 m 21 33 40 48 20 m 21 33 40 48 30 m 15 33 40 48 50 m 9 22 32 47 70 m 6 16 23 38 100 m 4 11 16 23 200 m 2 5 8 12 * Cable length is a total cable length between E-box and last connected Eminere. Example: Total cable length=L1+L2+L3 Notice for the E-box Star: The tables above state max. total number of Emineres connected to 6 LED outputs of the E-box Star (or max.
Eminere 200 m 9,18,27,36,45,54,60,72,81 90,99,108,117,126,135,144 153,162,171,180,189, EMINERE 2 22,44,66,88,110, 32,64,96,128, 132,154,176 160 47,94,141, 188 Max.
Eminere EMINERE 4 Max. number of Emineres 4= 48 Voltage Cable length 120V 190V 230V 277V 10 m 21,42 33 40 - 20 m 21,42 33 40 - 30 m 15,30,45 33 40 - 50 m 9,18,27,36,45 22,44 32 47 70 m 6,12,18,24,30,36,42 16,32 23,46 38 100 m 4,8,12,16,20,24,28,32,36, 40,44 11,22,33,44 16,32 23,46 200 m 2,4,6,8,10,12,14,16,18,20, 22.24.
Eminere The Cable gland M20x1.5 for Power IN (5) is intended for a cable of a diameter of 7-13mm. Remove the end cap from the cable gland before passing the cable. Power connection L N Core (EU) Braun Blue Green/yellow Core (US) Black White Green (earth) We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of the cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on the thread of the gland body.
Eminere 3. Screw the cover (2) back on the Booster box.
Eminere 4.
Eminere IP67 • E-box Lite 1 output 1 Main power Input Control: DMX, W-DMX control, RDM Pixel control (1px= 1ft) 120-277V Input Connection via screw terminal blocks, inlets via grommet IP67 Mounting method • Via two L-shape brackets • LED module “tilt” adjustment range: -95°/+95° Sizes • Eminere 1 (300mm / 1ft) • Eminere 2 (600mm / 2ft) • Eminere 3 (900mm / 3ft) • Eminere 4 (1200mm / 4ft) Housing • Aluminium extruded body with die-casted end caps • Tempered glass Cooling system • Convection Total heat diss
Eminere Weight •Eminere 1: 2.5 kg (5.5 lbs) •Eminere 2: 4 kg (8.82 lbs) •Eminere 3: 6.02 kg (13.27 lbs) •Eminere 4: 7.
Eminere • Booster box Included items • 1 x Eminere • 1 x User manual Optional accessories Leader cables: P/N 13053005 Cable CE Leader FF 2m ABB1-DFQ06 P/N 13053006 Cable CE Leader FF 5m ABB1-DFQ06 P/N 13053007 Cable CE Leader FF 10m ABB1-DFQ06 P/N 13053008 Cable CE Leader FF 25m ABB1-DFQ06 P/N 13053009 Cable CE Leader FF 50m ABB1-DFQ06 P/N 13053010 Cable US Leader FF 2m ABB1-DFQ06 P/N 13053011 Cable US Leader FF 5m ABB1-DFQ06 P/N 13053012 Cable US Leader FF 10m ABB1-DFQ06 P/N 13053013 Cable US Leader FF 25
Eminere P/N 13053016 P/N 13053017 P/N 13053018 P/N 13053019 P/N 13053020 P/N 13053021 P/N 13053022 P/N 13053023 P/N 13053024 P/N 13053025 P/N 13053026 P/N 13053027 P/N 13053028 P/N 13053029 P/N 13053030 P/N 13053031 P/N 13053032 P/N 13053033 P/N 13053034 P/N 13053035 P/N 13053036 P/N 13053037 P/N 13053038 P/N 13053039 P/N 13053040 P/N 13053041 P/N 13053042 P/N 13053043 P/N 13053044 Cable CE Leader MM 5m ABB1-DMQ06 Cable CE Leader MM 10m ABB1-DMQ06 Cable CE Leader MM 25m ABB1-DMQ06 Cable CE Leader MM 50m AB
Eminere P/N 10980487 P/N 10980488 P/N 10980489 P/N 10980490 P/N 10980491 Cable Cover for Eminere 4 RAL9011 Shield for Eminere 1 RAL9011 Shield for Eminere 2 RAL9011 Shield for Eminere 3 RAL9011 Shield for Eminere 4 RAL9011 5. Cleaning and maintenance DANGER ! Disconnect from the mains before starting any maintenance or cleaning work Rinse off loose dirt with low pressure water spray. Wash the housing with a soft brush or sponge and a mild, nonabrasive washing detergent. Rinse it.