User Manual
Eminere
9
EMINERE 4
Voltage
Cable length *
120V
190V
230V
277V
10 m
21
33
40
48
20 m
21
33
40
48
30 m
15
33
40
48
50 m
9
22
32
47
70 m
6
16
23
38
100 m
4
11
16
23
200 m
2
5
8
12
* Cable length is a total cable length between E-box and last connected Eminere.
Example: Total cable length=L1+L2+L3
Notice for the E-box Star: The tables above state max. total number of Emineres connected to 6 LED outputs
of the E-box Star (or max. number of Emineres connected to one output if the rest of outputs is not connected).The
E-box Star has only one power input!
3.3 The Booster box
To compensate a voltage drop in large installation, the Booster boxes have to be connected in the chain of
Emineres at every LED output of the E-box.
The following tables give numbers of Emineres after which the Booster box has to be installed in the chain of
Emineres (at one LED output of the E-box). The following tables apply for the Standard mode of E-boxes.
EMINERE 1 Max. number of Emineres 1= 191
Voltage
Cable
length
120V 190V 230V 277V
10 m 83,166 131 159 -
20 m 83,166 131 159 -
30 m 58,116,174 131 159 -
50 m 35,70,105,140,175 88,176 128 186
70 m 25,50,75,100,125,150,175 63,126,189 92,184 133
100 m 17,34,51,68,85,102,119,
136,153,170,187
44,88,132,176 64,128 93,186