Instruction Manual

INSTALLATION INSTRUCTIONS
CALUMMA M / L / XL SC AND MC
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com
VERSION 3.0 / 2_2023
5
F
DMX or ETHERNET via E-Box with Leader and Jumper Cable
Please align the arrow symbol and mate the connector. Do NOT
rotate the connector. Correct connection should be signalized
by silent „click“ sound.
Mating complete.
Rotate NUT 30 degrees anti-clockwise, same as the arrow di-
reciton. (Please do not rotate clockwise during unmating pro-
cess)
Drop out.
LOCK
UNLOCK
1 2
1 2
CONNECTION - US
(JUNCTION BOX IS NOT PART OF THE PACKAGE)
Connection – colour coding
WIRE
POWER
CONNECTION
WIRE
DATA
CONNECTION
Black L Red Data + (+)
White N Orange Data - (-)
Green/Yellow / Data 0V (0)
next
Junction Box
CalummaDALI
Power
Junction Box
A
DALI
FBFA