8
9
4.3 DMX-512 connection/connection between xtures
The xture is equipped with 3-pin XLR sockets for DMX input and output.
Only use a shielded twisted-pair cable designed
for RS-485 and 3-pin XLR-plugs and connectors in order to connect the controller with the xture or one xture with
another.
Occupation of the XLR-connection:
DMX - output DMX-input
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
Building a serial DMX-chain:
If you are using the standard DMX-controllers, you can connect the DMX-output of the controller directly with the DMX-
-input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to
use adapter-cables.
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always connect output
with the input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ohm resistor between
Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last xture.
Building a master/slave-chain:
Connect the DMX-output of the master xture in the data-chain with the DMX-input of the rst slave. Always connect output
with the input of the next slave until all slaves are connected (up to 32 xtures).
Caution: It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master xture and into the
output of the last slave xture in the link in order to ensure the proper transmission on the data link.
1 - Shield
2 - Signal (-)
3 - Signal (+)
Master/slave operation
DMX operation