17
3.It is recommended that you exit all programs before running the Software Uploader.
4.Start the Software Uploader program. Select desired COM and then click Connect button.
If the conection is OK, click Start Uploading button to start uploading. It will take several minutes to
perform software update. If the option "Incremental Update"isn´t checked ,all processors will be
updated (including processors with the same software version).
If you wish to update only later versions of processors, enable the Incremental Update check box.
Avoid interrupting the process. Update status is being displayed in the list window.
When the update is nished, the line with the text “The xture is successfuly updated‘ will appear in
this window and the xture will reset with the new software.
Note: In the case of interruption of the upload process (e.g. power cut), the xture remains in the update mode and you
have to repeat the software update again.
For example: The xture was switched off before nishing software upload. After switching the xture on again, the xture
is still in the update mode and the display is dark. Restart the Software Uploader program and repeat software update
from your PC.
8. Power down mode
This mode omits xture reset after switching the xture on and lowers motor powers of the xture. „Power down mode”
is useful in special casech. g. if the xture is in a ight case and you want to set its DMX address without taking it out
from the case. To enter „Power down mode”, press and hold [UP] and [DOWN] and at the same time switch on the Power
switch. The following message appears on the display: “P.d.Mo.”
Press [ENTER] to activate „Low power mode” without xture reset. Now you can set features and behaviour of the xture
by using “Pers.” menu. If you want to go „normal operation mode”, execute xture reset.
Note: All motors in “Power down mode” are deactivated.
9. Error and information messages
PA.Er. (Pan-yoke movement error)
This message will appear after the reset of the xture if the yoke’s magnetic-indexing circuits malfunction (sensors failed
or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The yoke is not located in the
default position after the reset.
ti.Er. (TILT-head movement error)
This message will appear after the reset of the xture if the head’s magnetic-indexing circuit malfunctions (sensor failed
or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The head is not located in the
default position after the reset.