DALI control 
Addressing of the fixture has to be made by means of an external DALI controller. 
If you need to start the permanent DALI control of the fixture (fixture will not respond to DMX commands), the 
external DALI controller has to send activating command (8=ON). 
If you need to stop the permanent DALI control of the fixture, the external DALI controller has to send deactivating 
command (0=OFF). 
3.2 0-10V control 
DIP 11 has to be set in ON position. 0-10V operation has priority to DALI and DMX commands. The option is 
applicable for the PW and TD version of the Ambiane SP16 only. 
4. RDM 
This fixture supports RDM operation. RDM (Remote Device Management) is a bi-directional communication 
protocol for use in DM X512 control systems, it is the new open standard for DMX512 device configuration and 
status monitoring. 
RDM allows you to set a DMX address, select DMX mode, readout software version of the fixture etc. It is also used 
for fixture software update by means of the Robe Uploader. 
RDM model ID for the Ambiane SP16 0x012b. 
Parameter ID
Discovery 
command 
SET command
GET command
DISC_UNIQUE_BRANCH
* 
DISC_MUTE
* 
DISC_UN_MUTE
* 
DEVICE_INFO
* 
SUPPORTED_PARAMETERS
* 
SOFTWARE_VERSION_LABEL
* 
DMX_START_ADDRESS
*  * 
IDENTIFY_DEVICE
*  * 
DEVICE_MODEL_DESCRIPTION
* 
MANUFACTURER_LABEL
* 
DEVICE_LABEL
*  * 
DMX_PERSONALITY
*  * 
DMX_PERSONALITY_DESCRIPTION
* 
RESET_DEVICE
*
SENSOR_VALUE
*
* 