User Manual

3
DMX connection 0-10V connection Power connection
PCB Function PCB Function PCB Function
0V- Shield 0V 0V + Power+
D+ Signal(+) D+ +10V - Power-
D- Signal(-)
RecommendeddiametersofconductorswithrespecttodistancebetweenAmbianeAPandpowersupplyunit
(AmbianePowerAP).
Distance/cable length 50m 100 m
Diameters of conductors 0.5mm
2
1 mm
2
3. DMX and DALI address setting and control
TheDIPswitch(7),locatednexttotheconnectionblocks,allowsyoutorunatestlightandswitchtheAmbiane
APtotheupdatemodeincaseofsoftwareupdate.
.
DIP10-ifswitchedtoON=testlight(3200KforRGBWandTWversion)
DIP11-selectionofxturecontrol:OFF=DMX512orDALI,ON=0-10V
DIP12-changefromOFFtoONpositionswitchestheAmbianeAPtotheupdatemode(switchingtotheupdate
modeisnotnecessaryiftheRobeUploaderisusedforAmbianeAPupdate).
DMX control
TheDMXstartaddress,istherstchannelusedtoreceiveinstructionsfromtheDMXcontroller.Theaddress
maybeanychannelfrom1to509.DMXaddresscanbeseteitherbyDIPswitchorbyRDM.DMXaddress
setbyRDMoverwritesaddresssetbyDIPswitchandviceversa.ThegreenLED(8)onthePCBsignalsway
ofDMXaddresssetting:
LEDlights-DMXaddressissetbymeansoftheDIPswitch.
LEDdoesnotlight-DMXaddressissetbymeansofRDM.
DIP11hastobesetinOFFposition.
ExampleofDMXaddresses:
DALI control
AddressingoftheAmbianeAPismadebymeansofanexternalDALIcontroller.TheexternalDALIcontroller
hastosendactivatingcommand(8=ON)ifyouneedtostartthepermanentcontroloftheAmbianeAP(Ambiane