User Manual

2
2. Installation
1.Prepareacircularopeninginthelowerceiling(1)asshowninthepicturebelow.
2.InserttheAmbianeAPunitintotheopening.FastentheAmbianeAPbymeansoftwospringfasteners(2)
to the opening.
3.ConnectneededcablestotheAmbianeAP.Connectionblocks(4)areplacedonthePCBRB3727(3).The
PCBisunderplasticcover(5)whichisfastenedbymeansoftwoscrews(6).
Theprimarypowerinputservesforastandardpower(e.g.PowerSupplyforAmbianeAP).
Thesecondarypowerinputservesforabackuppower(incasethatprimarypowerfailed).
Ifbothpowerinputsareundervoltage,theprimarypowerhasapriorityandthesecondarypowerisdisabled.
Incaseofprimarypowerloss,thesecondarypowerisenabled.
IftheAmbianeAPissuppliedviathesecondarypower,thelightintensitycanbesetbythetrimmer(9).
TheAmbianeAPcanbecontrolledbyoneofthefollowingmethods:DMX512
DALI
0-10V(AmbianePW,AmbianeTDonly)
TheAmbianeAPisequippedwithtwoDMXandDALIconnectionblocksforeasyconnectiontoDMXorDALI
chain(In/Outmethod).