Zone Control (Entry and Exit)
You can of course extend your zone control to monitor entry and exit.
VSA 1
Trigger: - Function 1 ON
Reset: - Input 3 ON (Exit Mat)
Function 1
Condition 1: - Input 1 ON (viewing Mat)
Condition 2: - Function 2 ON
Operator: - AND
Function 2
Condition 1: - Input 2 ON (Entry Mat)
Condition 2: - Input 3 ON (Exit Mat)
Operator: - LATCH
With this version stepping on the viewing mat alone is not enough to trigger the
routine. The viewer first has to enter the area and step on the entry mat. The latch
function of Function 2 remembers that someone has entered. Stepping on the viewing
mat will then trigger the routine. Leaving the area will reset the routine.
This example raises an interesting possibility for Exorcist, you could introduce a
puzzle element to your haunt…..
If all else fails make sure you have a manual override
Whilst this chapter has dealt with fully auto haunts, sometimes it is desirable for the
Hauntmaster to be able to just override the program and have it do what he wants; this
is ideally what the IR remote is for.
VSA 1
Trigger: - Function 1 ON
Reset: - Function 4 ON
Function 1
Condition 1: - Function 3 ON
Condition 2: - IR RC 1 ON
Operator: - OR
Function 2
Condition 1: - Input 2 ON (Ent Mat)
Condition 2: - Function 4 ON
Operator: - LATCH