Specifications
1
BooBox FlexMax FI-216 Operating Manual - page 9
2
Trigger Inputs
About the Trigger Inputs
The trigger inputs are used to activate your scenes automatically when a sensor picks up movement. Trigger
Inputs are activated when 5 to 24 volts A.C. or D.C. is applied to the input terminals. The inputs are optically-
isolated, which means they are electrically isolated from the sensitive electronics inside.
You’ll need to supply power to the inputs in order to trigger them, in most cases this power can be “borrowed”
from the power terminal block as shown below. This method negates the optical isolation, but for most setups
this is completely fine. For complete optical isolation see Optically Isolating your Trigger.
Wiring Diagrams