User manual

LOR800W & LOR160xW g3
25
Connected to LOR Network:
The display steadily shows “L-01,” meaning the
controller is set to LOR Unit ID 01.
Connected to DMX Universe:
The display steadily shows “d001” meaning the
controller is set to DMX address 001.
Loading Firmware:
Resetting:
“0000” is displayed for a couple of seconds while
the controller is resetting. See the Resetting the
Controller section for more information.
Running a Standalone Sequence:
LOR800W & LOR160xW g3
26
Assigning a DMX Address
To set the DMX Address, press the Select/Set
button until the status display flashes “dnnn” where
nnn is the current DMX address. Use the and
buttons to select the DMX address you want and
then press the Select/Set button to save the DMX
address. You can hold the or button down to
scroll through addresses.
You can also set the DMX Address with the
Hardware Utility. In this case you set the Unit ID
which sets the DMX address to (((Unit ID) – 1) * 16)
+ 1. See the Setting the Unit ID with Software
section.
A cable that plugs into one of the controller’s RJ45
jacks and terminates with in a male XLR-3 plug is
available here: www.lightorama.com LOR Store
Accessories RJ-45 to XLR 3-Pin Male
Assigning a Unit ID
To set the Unit ID, press the Select/Set button until
the status display flashes “L-nn” where nn is the
current Unit ID. Use the and buttons to select
the Unit ID you want and then press the Select/Set
button to save the Unit ID. You can hold the or
button down to scroll through IDs.
You can also set the Unit ID with the Hardware
Utility. This will also set the DMX address to (((Unit
ID) – 1) * 16) + 1. See the Setting the Unit ID with
Software section.
Each LOR light controller used in a network must
have a unique ID assigned. [If two controllers are
given the same unit ID, then they will both perform
the same effects.] Every channel that you control in