User Manual

Flash Power Output
The flash power output is variable over a four f/stop range (five f/stops) from full power
to 1/16 power in 1/10 f/stop increments. The power is displayed on the LCD screen.
Minimum setting is 2.0 and the maximum is 6.0. Pressing the up and down touch-pad
buttons under the LCD changes the value by 0.1 f-stop (a total of 40 values). If the
current value is 5.6 and you want to reduce the power by one stop, set the power to 4.6.
Flash Settings
SETTING POWER
6.0 Full Power
5.0 1/2 POWER
4.0 1/4 POWER
3.0 1/8 POWER
2.0 1/16 POWER
6