MULTY
Chilling/freezing cycle by time organized by load levels.
The number of levels available varies depending on the equipment.
1. Select MENU by rotating the knob
SOFT 0°F
HARD 0°F
IFR INFINITY
SOFT +37°F
HARD +37°F
MENU
2. Press the knob to enter section MENU
SOFT 0°F
HARD 0°F
IFR INFINITY
SOFT +37°F
HARD +37°F
MENU
3. Select MULTY by rotating the knob
4. Press the knob to enter section MULTY
5. Enter the time for each level and
confirm it with the knob
During the cycle it is possible:
- to view and modify the default parameters by
selecting SET (see page 41)
- to stop the cycle by selecting
Note: the modified parameters will be saved
At the expiry of the set value for each
individual level, the buzzer and the
flashing value alert the user that the
product can be withdrawn.
Once all the set times have expired,
automatic conservation phase
During conservation it is possible:
- to view and modify the default parameters by
selecting SET (see page 41)
Note: the modified parameters will be saved
2
1 30'
MENU
MULTY
5L
3 0'
5 0'
4 0'
+80°F
+75°F
SET
20'
2
1 30'
MENU
MULTY
5L
3 0'
5 0'
4 0'
+80°F
+75°F
SET
20'
AUTOMATIC
MULTY
COOLING
STORED
SETTING
SERVICE
HACCP
FUNCTIONS
MENU
AUTOMATIC
MULTY
COOLING
STORED
SETTING
SERVICE
HACCP
FUNCTIONS