User Manual
Table Of Contents
31
3283430_GB
COOLING
It is advisable to run a cooling cycle prior to selecting any chilling cycle.
1. Select MENU by rotating the knob
SOFT 0°F
HARD 0°F
IFR INFINITY
SOFT +37°F
HARD +37°F
MENU
2. Press the knob to enter section MENU
SOFT 0°F
HARD 0°F
IFR INFINITY
SOFT +37°F
HARD +37°F
MENU
3. Select COOLING by rotating the knob
4. Press the knob to activate the selected
cycle
During the cycle it is possible:
- to view and modify the default parameters by
selecting SET (see page 41)
- to stop the cycle by selecting STOP
Note: the modified parameters will be saved only
for the cycle in progress
--
COOLING
100%
+80°F
+75°F
SET STOP
5. Cycle ended, automatic conservation
phase
During conservation it is possible:
- to view and modify the default parameters by
selecting SET (see page 41)
- to stop the cycle by selecting STOP
Note: the modified parameters will be saved only
for the cycle in progress
--
END CYCLE
CONSERVE
100%
+80°F
+75°F
SET STOP
AUTOMATIC
MULTY
COOLING
STORED
SETTING
SERVICE
HACCP
FUNCTIONS
MENU
AUTOMATIC
MULTY
COOLING
STORED
SETTING
SERVICE
HACCP
FUNCTIONS
MENU