4
-
Use and installation manual
Contact one of the authorised service centres for all requirements.
When requesting service, state the data provide on the nameplate and provide a de-
scription of the fault.
This unit is capable of reducing the temperature internal the contents from 135°F
(57°C) to 40°F (4°C) with in 4 hours, in order to conserve it for a long period of time
without altering the organoleptic characteristics.
Machine capacity as to the quantity to be cooled depend on the model purchased.
PROCEDURE FOR REQUESTING SERVICE
TECHNICAL INFORMATION
2
GENERAL DESCRIPTION OF APPLIANCE
TECHNICAL DATA
B151HU B151MU B152MU B1101SU
Gross weight (lb)
309 309 342 507
Net weight (lb)
276 276 320 452
Dimensions
36.57"x30.67"x
33.07"
29.38"x28.38"x
38.19"
34.29"x35.51"x
37.28"
31.49"x32.68"x
73.23"
Capacity
Mass /cycle [lb] (+194°F ÷ +37°F)
35 48 55 100
Mass /cycle [lb] (+194°F ÷ 0°F)
22 28 33 60
Net internal volume [cuft]
2.55 2.55 3.5 5.52
Grids
3 3 3 3
Power supply
Voltage [V]
220 ~ 220 ~ 220 ~ 220 ~
Frequency [Hz]
60 60 60 60
Phase
1 ph 1 ph 1 ph 3 ph
Intensity [A]
6 6 6,13 8.5
Power input [W]
1122 1139 1520 2625
Refrigerating unit
Refrigerating power [W]
1054 1054 1319 2604
Evaporation temperature [°F]
-22 -22 -22 -22
Cooling temperature [°F]
+194 ÷ +37 +194 ÷ +37 +194 ÷ +37 +194 ÷ +37
Cooling time [min]
90 90 90 90
Freezing temperature [°F]
+194 ÷ 0 +194 ÷ 0 +194 ÷ 0 +194 ÷ 0
Freezing time [min]
240 240 240 240
Condensation temperature [°F]
+130 +130 +130 +130
Max room temperature [°F]
+90 +90 +90 +90
Compressor type
Ermetic Ermetic Ermetic Ermetic
Refrigerant name
R404A R404A R404A R404a
Mass of refrigerant [lb]
3 3 3.3 4.4
Condesation air
Air Air Air Air
Noise [dB] (A)
65 65 65 72
IFR
Multi-detector probe