Instruction manual
32T
. est operation
~
CAUTION
Danger
of
exhaust
disruption
Remove
blank
flange
from
inlet
and
outlet.
Operation with blank flange being fitted can disrupt air flow or cause blank flange to fly
by exhaust impetus, resulting
in
accident, failure, or bodily injury
from
contact with flying
objects.
Danger
of
foreign
matter
entering
inlet
When checking turning direction,
be
careful not to enter foreign matter into
an
inlet. Foreign matter entering inlet can cause failure.
I Test operation I
CD
Open inlet and outlet
Remove blank flanges
(2
places)
from inlet and outlet of
vacuum pump.
~
Check
turning direction
Blank Flange
O-fing
0
Remove blank
flange
0
Prevent foreign
matter from
enterin~
Open inlet, turn on electrical source
to
start operating vacuum pump.
Vacuum pump turns clockwise
when viewed from motor side.
Di",cticm plate
Turning
Check that comes out of air outlet.
If air does not come out from outlet, vacuum pump of three-phase motor may turn
in
reverse.
In
that case, stop vacuum pump, turn
off
main electrical source and change 2 out
of 3 wires of electric source connection and change turning direction to correct one.
If you fit pump to vacuum system and control operation of vacuum pump by
-17-