Instruction manual

!How to wire !
Q)
Remove 4pcs. of
M5
bolt at motor terminal box and remove protection cover.
*
Be
careful not to lose removed
M5
bolts and washer.
® Wiring diagram
is
shown inside protection cover.
Single1)hase specifications
You can change to a
100V or 200V connection by changing terminal plate (2pcs
.)
.
*
It
is
wired
to
200V
when
delivered
to
you.
If you want to change to a 1
OOV
connection, remove
M4
nut of electric source
terminal and change terminal plate
as
illustrated below.
Insert electric
source cord through cable1Jland
on
the right side of terminal bo
x.
El
ect
ri
c
So
ur
ce
Terminal
M4
Nu
Terminal Block
Three1)hase specifications
Terminal plate (
2pC5
)
200V
Connec
ti
on
(When delivered to you)
Ground Terminal
MS
Bolt
o o
100V Co
nn
ection
You can change to a 200V or 400V connecti
on
by changing terminal plate (3pcs.).
*
It
is
wired
to
200V
when
delivered
to
you.
If you want to change to a 400V connection, remove M4 nut of electric source
terminal and change terminal plate as illustrated below.
Insert electric
source cord through cable1Jland on the bottom side of terminal box.
Connect each phase L
1-t.2-t.3 to each electric source terminal respectively
in
accordance with the below wiring diagram.
Ground Terminal
MS
Bolt
Electric Source
I
200V Co
nn
ection
(When de
li
vered to you)
-
16
-
0
;---
_____
0
400V Co
nn
ection