Operating Manual

Operating manual: Metris Vibe
Rev.: 03
ANDRITZ
Page 20 of 25
March 22, 2022
7. TECHNICAL DATA AND AMBIENT CONDITIONS
Measurement:
Vibration: x-axis, y-axis, z-axis
Temperature
Frequency Range:
10Hz - 12800Hz
Sampling
Frequency:
100 Hz - 25600Hz
Number of
measured values
per measurement
and axis:
Maximum 6000 samples
Sampling Time:
100ms - 5000ms
Sensitivity:
±8g, ±16g, ±32g
Data Acquisition:
16 bit ADC
Measurement
interval:
User defined
Storing of Samples:
Depending on the used mode there is a different amount of
measurements which can be stored directly on the Metris Vibe
Standard Mode (3200Hz, 640ms): 82 measurements
High Frequency Mode (12800Hz, 320ms): 47 measurements
High Resolution Mode (3200Hz, 1280ms): 47 measurements
MCU:
Ultra low power consumption processor, 32 bit
RF Communication:
2.4 GHz Low Power, BLE
Software:
Over the Air firmware update
Battery life time:
Up to 3 years, depending on the sampling settings
Mounting
orientation:
All orientations
Mounting System
Connection:
M8 x 1.25 thread
EN 60529
protection:
IP69K
Temperature range:
-40°C to 85°C
Dimensions:
Ø34.6mm x 24mm
Weight:
60g
Max. surface
temperature:
Ambient temperature
Battery:
CR2477N, 3V, Lithium, 950mAh
Max. current
10mA
Nom. current
0.02mA
Use of certain
hazardous
substances in
electrical and
electronic
equipment
according to
2011/65/EU
Restricted substances referred to in Article 4 (1) and maximum
concentration are in tolerance