User's Manual
Table Of Contents
- 1. General
- 2. Introduction
- 3. Functional Description
- 4. Commissioning
- 4.1. General
- 4.2. High Power RU Mechanical Installation
- 4.3. Electrical Installation
- 4.3.1. Health and Safety for electrical installation
- 4.3.2. Property Damage Warnings for electrical installation
- 4.3.3. Connections
- 4.3.4. Grounding (Earthing)
- 4.3.5. Connection of the antenna cable
- 4.3.6. Mains power connection
- 4.3.7. Extension Unit port connection
- 4.3.8. External alarm In / Out port
- 4.3.9. RS 485 /+28 V port
- 4.3.10. Local interface port
- 4.3.11. Coupling Probe
- 4.3.12. Optical-fiber cable connection
- 4.3.13. Assembly instructions for optical LC patch cables
- 4.3.14. Optional equipment for optical fiber connection
- 4.4. Commissioning Flow-Chart
- 5. Alarms
- 6. Maintenance
- 7. Appendix
- 8. Index
4. Commissioning
Page 42 M0200A8C_uc_ION-U_H_7P_80-85P_17P_19P User’s Manual for ION
®
-U
4.3.13.1. Assemble optical Opus short plug components
The following instructions cover both simplex and duplex fiber cables. Steps that
apply only to duplex cables have “b” following the step number.
Unscrew the nut and take out the plug clamp. Slide the adaptor nut and the
clamp onto and along the fiber patch cable as shown.
figure 4-23 Opus short plug clamp and nut
Simplex Cable
Duplex Cable
Place the simplex split gasket
on
the cable using the split on the side of
the gasket with the larger diameter of
the gasket toward the front.
Place the duplex split gasket
on the
cables using the split on both sides of
the gasket with the larger diameter of the
gasket toward the front. Ensure that the
channel positioning is correct as shown.
figure 4-24 Simplex split gasket figure 4-25 Duplex split gasket
4
3
2
1
1
2
2b
Flat surface
Channel B
Channel A
Flat surface