User's Manual
4. Commissioning
Page 28
7.Manual MF0200A0A ION-U_H_17P2_uc_19-July-13.docx
User
’
s Manual for ION
®
U
Coninvers M17 –
Series P20, 4-Pin
Pin Name Color
1 Phase Black
2 Neutral White
3 n.c. n.c
PE Ground Green
figure 4-10 Mains power cable - AC
table 4-3 AC power cable
For the AC power supply connection, a minimum cross section of 1.5
mm
2
is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
Note: Do not connect or disconnect the power cord at the mains connector
while power is on. Turn off mains* power before connecting the
power cord at the remote unit, then, engage mains again.
* Mains power must be interrupted with an external mains breaker. For the mains breaker, observe
the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is
needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or
16 Amps for 240-Volt service.
4.2.6. Extension Unit Port Connection
The EU connector is used to connect a cable bridge to an optional Extension Unit to
provide additional bands of coverage. This port provides control and RF signaling to
and from the extension unit.
Front View
7-Pin
Pin Assignment
1 RF
2
n.c.
3 System Bus
4
RF (if Pin installed)
5 System Bus
6
n.c.
7 RF
figure 4-11 EU (Extension Unit) connector table 4-4
EU Connector
white
black
green
Protective Cap
PE
1
2
3
Mains Cable Connector
Front View
B0405ADA