User's Manual

4. Commissioning
Page 20
7.Manual MF0200A0A ION-U_H_17P2_uc_19-July-13.docx
User
s Manual for ION
®
U
figure 4-3 Pole mounting drawing
Ensure that there is free access to the electrical connections as well as to the
cabinet. The approved bending radius of the connected cables must not be
exceeded.
4.1.4. Mounting of Fan Protection
Fan protection is required for the outdoor usage of a stand-alone remote unit.
Mounting of the optional fan protection is described below.
To install the protective cover of the fan protection kit, first remove the four screws
with their respective lock washers from the cover of the air inlet of the remote unit,
and replace them with four spacing bolts M4.0x30 with the four lock washers
M4.0 DIN125 that are part of the fan protection kit.
Place the protective cover into position by aligning its four bore holes over the
spacing bolts and fasten it using the original lock washers and screws of the
remote unit. (These lock washers and screws are also part of the fan protection
kit and can be used as spare parts in case of loss.)
Nut M8 DIN 934
Optical remote unit