4. Commissioning
7.Manual MF0200A0A ION-U_H_17P2_uc_19-July-13.docx User’s
Manual for ION
®
U
Page 17
9. A spacing of 40 mm (1.66 inch) around the unit is required.
10. To ensure sufficient airflow when mounting the unit in enclosed spaces, two
lid openings (one for the air inlet and the other for the air outlet) must be
provided. Do not block these air inlets and outlets when mounting the
remote unit. The size of each opening must equal at least 12 x 12 cm (144
cm
2
). Ensure that there is no thermal short circuit between the air inlet and
air outlet.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by the manufacturer. Ensure that the
static and dynamic strengths are adequate for the environmental conditions of the
site. The mounting itself must not vibrate, swing or move in any way that might cause
damage to the Remote Unit.
Specified torques must be observed for certain mounting procedures according to the
following table:
Type
Tallow-drop
screws
Hex
nuts
Spacing
bolts
PG
(plastic)
PG
(aluminium)
Thread
M 4 M 8 M 4 M 8 PG 13.5 PG 29
Specified torques
3.3 Nm 27 Nm 2.3 Nm 27 Nm 3.75 Nm 10 Nm
table 4-1 Specified torques
The mounting procedures for a stand-alone remote unit without optional accessories
are described and illustrated in the following sections. For further information
regarding special mounting procedures including mounting of accessory equipment,
please see the separate accessories manual.