User's Manual
5. Low Power EU Maintenance
Page 52 7.Manual ION-U_EU_L_23_23 M0F200AFA.docx
3. Locate the power supply on
the right side of the Extension
Unit.
figure 5-2 EU power supply location
4. Use a #2 Phillips head or
slotted screwdriver to loosen
the 8 universal slot/Phillips
captive power supply screws
and carefully remove the
supply. The weight of the
power supply must be
supported as you loosen the
screws to prevent damage to
the supply.
figure 5-3 8 EU power supply screws
5. Carefully remove the power
supply from the unit. Do not
attempt to support the weight
of the supply with the attached
input and output cables.
figure 5-4 EU power supply with cables
Mains
connecto
r
Power
supply
Loosen 8 universal
slot/Phillips screws