User's Manual

4. Commissioning
Page 22 7.Manual ION-U_EU_L_23_23 M0F200AFA.docx
5. Notice: If any different or additional mounting material is used, ensure that the
mounting remains as safe as the mounting designed by the manufacturer. The
specifications for stationary use of the Unit must not be exceeded. Ensure that
the static and dynamic strengths are adequate for the environmental conditions
of the site. The mounting itself must not vibrate, swing or move in any way that
might cause damage to the Unit.
Specified torques must be observed for certain mounting procedures according to the
following table:
Type Pins Hex nuts Screws
Thread
M 6 M 6 M6
Specified torques
3.3 N-m 3.3 N-m 3.3 N-m
table 4-1 Specified torques
4.1.3. Mounting bracket
4.1.3.1. Mount to a wall
1. Check the suitability of the wall-mounting kit and the wall.
2. Install the mounting bracket using 4 M6 screw anchors (not included*) or suitable
lag bolts according to the drilling layout. Confirm that the bracket is securely
fastened to the wall. Installer must verify that the supporting surface will safely
support the combined load of the electronic equipment and all attached hardware
and components.
* The M6 screw anchors are not included as part of the EU delivery because the suitable type
depends on the on-site conditions (wall structure and materials). Use screw anchors that are
appropriate for the mounting surface.
figure 4-1 Mounting bracket