4. Commissioning
M0200A9C_uc_ION-U_EU_H_7P_80-85P_17P_19P User’s Manual for ION
®
-U Page 35
4.3.6.2. Mains power connection DC
Caution: Danger of electrical hazard by high current. Disconnect mains
power before opening the DC connector housing.
Note: The Mains cable must be properly secured observing local regulations and
electrical codes. Be sure to allow enough slack in the cable at the EU to
mount or
dismount the cable into the DC Mains connector of the EU.
Unscrew the two M3 x 12 captive screws
and take off the cover from the DC Mains
connector housing.
At the EU housing
the cover is inserted into a recess, so first
lift the cover at the front and carefully pull
it out from the recess.
Then remove the rubber plug.
Double lug DC cable connectors need to
be M6 with a stud hold spacing of 15.88
mm (5/8”).
Rubber
plug