User's Manual
Table Of Contents
- 1. General
- 2. Introduction
- 3. Functional Description
- 4. Commissioning
- 4.1. General
- 4.2. High Power EU Mechanical Installation
- 4.3. Electrical Installation
- 4.4. Commissioning Flow-Chart
- 5. Alarms
- 6. Maintenance
- 7. Appendix
- 8. Index
4. Commissioning
M0200ABA_ION-U_EU_H_23_23 User’s Manual for ION
®
-U Page 21
3. Hang the Extension Unit into the upper bracket, insert it into the lower bracket,
and fasten it to the lower bracket with the M8x25 screws (C), split lock washers
(D) and washers (E), see chapter 4.2.4.
The maximum diameter of the pole or column must not exceed 120 mm (4.7 inch).
figure 4-6 Pole mounting – max. diameter
4.2.6. Pole mounting procedure with brackets
The pole-mounting kit with brackets includes
• two mounting brackets (A), two counter brackets (B), four threaded bolts (C),
flat (F) and split lock (G) washers, hexagon (E) and locking (D) nuts to mount
the brackets to the pole
• and two M8x25 screws (H), flat (F) and split lock (G) washers to attach the
Extension Unit to the bracket.
figure 4-7 Pole mounting – with brackets
1
2
0
m
a
x
.