User's Manual

4. Commissioning
Page 26
7.Manual MF0200A0A ION-U_EU H 19P2_uc_08-July-13.docx
User
s Manual for ION
®
U
The selection of cable and antenna is an important consideration. On the one hand, a
cable with higher loss is less expensive but, on the other hand, it impairs
performance.
Use an appropriate torque wrench to tighten the 7/16 DIN-type (1 ¼ -inch
opening) antenna connectors to a coupling torque of 25 N-m / 19 ft lb.
Torque wrench item no. 244377, available from the CommScope e-
catalog, is recommended. Do NOT use your hands or any other tool (e. g.
a pair of pliers)! This might cause damage to the connector and lead to a
malfunction of the Remote Unit or increased PIM.
To minimize passive inter-modulation (PIM) distortion, attention must be
paid to the physical condition of the connector junctions. Do not use
connectors that show signs of corrosion on the metal surface. Prevent
the ingress of water into the connector. Attach and torque the
connectors properly.
An example of the antenna port connections for a Remote Unit paired with an
Extension Unit using an optional crossband coupler is shown below.
figure 4-8 Antenna port to CBC
wiring
1. Connect an RF cable from the ANT
port of the EU to the PCS input of the
CBC.
2. Connect an RF cable from the ANT
port of the RU to the AWS input of the
CBC
3. Route the antenna cable from the
antenna or splitter to the CBC.
4. Cut the cable to length and terminate
the cable with a 7/16 DIN type male
connector.
5. Using an appropriate torque wrench,
connect the antenna cable to the
Common port of the CBC.
EU
RU
CBC
RF
Cables
COM: Connect to antenna
or antenna network