-U Page 57
4.5.3. Status LED alarms
For local supervision, a status LED on the connector panel of the Remote Unit
adjacent to the Expansion ports provides a visual warning of an alarm condition. The
color of the LED indicates the severity of the alarm. Detailed alarm information is
available through the ION-U software interface. This table lists the alarm conditions
and possible on-site measures that could be performed to resolve the issues
responsible for triggering the alarms.
Alarm Name Description Remedy
Default
Severity
LED
DL optical power fail
Received optical power
below minimum threshold
check fiber connections and
transmitted optical power
major Red
Temperature Alarm temperature too high check ventilation and environment warning Green
VSWR Alarm
bad RF cabling /
mismatched antenna
check cable / antenna critical Orange
RF Low Output
CELL700
RF signal too low
check BTS output level/attenuator
configuration/RF cabling
minor Green
RF Low Output CELL
850
RF signal too low
check BTS output level/attenuator
configuration/RF cabling
minor Green
RF Low Output LMR
800
RF signal too low
check BTS output level/attenuator
configuration/RF cabling
minor Green
RF Low Output PCS
1900E
RF signal too low
check BTS output level/attenuator
configuration/RF cabling
minor Green
RF Low Output AWS RF signal too low
check BTS output level/attenuator
configuration/RF cabling
minor Green
DL CELL 700 band
alarm
hw failure in RF section change unit critical Red
DL LMR800+CELL850
alarm
hw failure in RF section change unit critical Red
DL PCS 1900E band
alarm
hw failure in RF section change unit critical Red
DL AWS band alarm hw failure in RF section change unit critical Red
UL CELL 700 band
alarm
hw failure in RF section change unit critical Red
UL LMR800+CELL850
band alarm
hw failure in RF section change unit critical Red
UL PCS 1900E band
alarm
hw failure in RF section change unit critical Red
UL AWS band alarm hw failure on RF section change unit critical Red
UL Overdrive/ALC
Limiting CELL 700
too high RF signal feeding
device
check unit/attenuator configuration minor Green
UL Overdrive/ALC
Limiting
LMR800+CELL850
too high RF signal feeding
device
check unit/attenuator configuration minor Green
UL Overdrive/ALC
Limiting PCS 1900E
RF signal feeding device
too high
check unit/attenuator configuration minor Green
UL Overdrive/ALC
Limiting AWS
RF signal feeding device
too high
check unit/attenuator configuration minor Green
Internal bus alarm
internal I2CBUS
communication malfunction
change unit critical Red
UL Laser Alarm
Uplink laser fail (cooling or
current failure)
change unit major Red